Pulse R™ | 24VDC

 
 
 
 
Back to List
$385.00
SKU: 305310
UPC: 305310
Qty:
Din Power Cable Size:

 

 

MORE INFO:   pdf  Pulse R Manual.pdf

The Pulse R is the ultimate solution for precision control of Unist’s Coolubricator™, Serv-O-Spray­™, and Saw Blade Lube™ systems. Choose from several operating modes for a greater range of control and make fine-tuned adjustments with digital display.
NOTE: Pulse R™ is only compatible with 24VDC voltage, PLEASE verify your system is 24VDC before purchase.

 

Benefits:

  • 25% faster performance
  • Unlock new operating modes
  • Precise electronic control
  • Retrofit existing systems

 

System Integration

Backwards compatible, the Pulse R works with new and existing Coolubricator,  Saw Blade Lube™, and Serv-O-Spray systems. The Pulse R ties into the system control solenoid valve and takes the place of the pneumatic pulse generator timer or logic block. Equipped with fault monitoring and visual feedback of output and input status, you can be confident that your system is working as it should be.

 

Coolubricator
CoolubricatorTM

When installed on a Coolubricator™, customers enjoy the continuous precision output of the system and can directly read and adjust the pump cycles per minute.

Serv-O-Spray
Serv-O-SprayTM

When installed on a Serv-O-Spray™, users can configure the Pulse R™ to dispense multiple shots of fluid with one input control signal.

Saw Blade Lube System
Saw Blade Lube SystemTM

When installed on a Saw Blade Lube System™, customers enjoy the continuous precision output of the system and can directly read and adjust the pump cycles per minute.

 


 

Modes

Mode 1: CONSTANT CYCLE ON POWER UP
When powered on, the pumps cycle at the rate displayed (indicated in cycles per minute) until power is disconnected. This is the default mode for Coolubricator™ and Saw Blade Lube System™ applications.

Mode 2: CONSTANT CYCLE ON TRIGGER
When powered on and the input trigger signal is detected, the pumps cycle at the rate displayed (indicated in cycles per minute) until the input is removed.

Mode 3: DELIVER # OF SHOTS ON POWER UP
When powered on, rapidly deliver the selected # of shots. Once power is turned off, repeat function. In Mode 3, the first digit on the display will be flashing “S”. This is the default mode for Serv-O-Spray™ applications.

Mode 4: DELIVER # OF SHOTS ON TRIGGER
When powered on and input trigger signal is detected, rapidly deliver the selected # of shots. Once input trigger signal is removed, repeat function. In Mode 4, the first digit on the display will be flashing “S”.

 

Pulse R
Pulse RTM

Features an easy to adjust, two-button display.

 

Specifications

Power supply: 24VDC, 12 watts

Input trigger signal: 24VDC

Output: 24VDC, 10 watt max

Maximum output cycle rate: 250 cycles per minute (modes 1 and 2)

Maximum shots delivered: 99 (modes 3 and 4)

 

Verifying 24VDC system actuation

24VDC system actuation can easily be verified by any of these 3 methods:

 

  1. Solenoid valve label
    Check the label on your system valve
  2. Unist part number decal
    Contact Unist with your system part number
  3. Verify with a multimeter
    Use a multimeter to verify 24VDC power input. (10% +/- 24vdc)

 

Determining Din power cable size

 

 

Customer Reviews

There are no customer reviews for this product. However, you can be the first person to add a review for this product.

Add Review

Add Review

 
 
 
 
 

(Your browser will be redirected back to this page)